WL3100/WL3100A Dry Pressure Transducer
WL3100 is a dry/dry differential pressure transducer. The difference between the pressure on the high and low pressure ports is linearized and converted to a usable 4-20 mA current output and made available as a digital serial SDI-12 output. The SDI-12 output… Read more
| Range | 0-5 m, 0-10 m, 0-15 m, 0-20 m, 0-40 m, 0-50 m water head | 
| Accuracy | +/-0.02 % FS (full temperature compensation) | 
| Overpressure | 2.67 x range | 
| Longterm Stability | Typically +/-0.05 % FS per annum | 
| Power Supply | Operating : 9.6 -16 V DC | 
| Outputs | 4-20 mA, SDI-12 (up to 60 m); RS232 (with optional SDI-12 to RS232 adapter SE231) | 
| Connectors | 
 | 
| Enclosure | Powder-coated aluminium | 
| Ingress Protection | IP65 | 
| Programmable LCD | 
 | 
| Pressure Transducer Connection | Pressure Transducer Connection | 
| Operating Temperature | 
 | 
| Operating Relative Humidity Range | 0 - 95 % non-condensing | 
| Dimensions and Mass | L x H x D: 180 mm x 105 mm x 100 mm; 1.2 k | 
WL3100 is a dry/dry differential pressure transducer. The difference between the pressure on the high and low pressure ports is linearized and converted to a usable 4-20 mA current output and made available as a digital serial SDI-12 output.
The SDI-12 output transmits up to a distance of 60 m (200 ft). The 4-20 mA and SDI-12 outputs can operate simultaneously allowing redundant connection to up to 2 data loggers or RTUs.
WL3100 and WL3100A are mounted in a vented rugged aluminium enclosure.
The WL3100 transducer is available as ‘stand alone’ for connection to HS23 dry bubble units or can be fitted as a component of the HS40 Series II or HS40 Compact bubbler system.
Two models: WL3100 and WL3100A
The two units share the same base technology and have very similar specs. The WL3100A is an advanced model with a wider temperature range starting at -40 °C and additional location correction factor to better account for atmospheric pressure influence, especially in particularly elevated or deep sites.
- High accuracy +/-0.02 % full scale
- Compatible with many pressure measurement applications
- Available in ranges from 5 m (16 ft) to 50 m (164 ft)
- SDI-12 and 4-20mA output at the same time
- Low power consumption
- Factory calibrated by KISTERS with certificate
- Surface Water
- Ground Water
- Waste Water
- Reservoirs and Dams
- Lakes
- 
																	Brochure WL3100/WL3100A
- 
																	Manual WL3100/WL3100A